Application:
  • Parallel measurement of two temperatures and Delta T, temperature setting overheating and further tasks depending on the connected device (eg. the analyzer HG3 determining the starting temperature of the evaporator, and thermocouple test ATC3 blocked filters).
Description:
ATH4, one of the measuring heads that can be used in Fieldpiece gauges or other, allows parallel measuring two temperatures. Since the type of thermocouple used depends on what will be the subject of measurement. Includes user receives two universal thermocouple type K, ATB1. However, the head can also connect other versions:
  • ATA1 - ATB1 with clamp thermocouple (the so-called. Alligator clip)
  • ATAF1 - thermocouple ATA1 version for high temperatures
  • ATWB1 - thermocouple designed to measure wet bulb temperature
  • ATF1 - thermocouple with a length of 15 cm intended for liquids,
  • ATP1 - thermocouple adapted to pierce the bodies of semi-
  • ATEXT10 - thermocouple extension cable 3 m
  • ATC3 - designed for thermocouple tubes.

Connected thermocouples give Fieldpiece ATH4 noted the tension that is translated into heat, but in the values expressed mVDC (in relation to 0.1mVDC 0.1º), by the meter set to such a range. The display included with the meter will give three values: the two thermocouples (T1 and T2) and Delta T.

Like other heads Fieldpiece, thermocouple thermometer can be connected directly to the universal metrics. For other tools, such as recorder and analyzer system DL3 HG3, use test leads or connector holder ADLS2 AHDL1. ATH4 thermometer will also collaborated with any digital multimeter equipped with a standard socket, input impedance 9 or 10 MW.

Highlights:
  • The administration of the two temperatures and the difference between these values in °F or °C, adjustable straight two switches;
  • Sensors thermocouples (in the shape of small balls on the ends of the cables) can measure the temperature of the air or surfaces that have contact;
  • The ability of converting temperatures between -45 °C - 980 °C (the highest temperature required type thermocouples available as an option);
  • Insulated thermocouple to a temperature of 200 °C;
  • Thermocouples shape allows them to wrap around the sensor cable for storage thermometer;
  • Plug-input thermocouple placed in the niche of the head to ensure stable test conditions;
  • to help measure the temperatures of pipes, the head is equipped with two strips of Velcro, holding the ends of thermocouples with pipe;
  • Technology used in the well head passes the test with regard to compensate for the rapidly changing external temperature, frequent situations in everyday work with the device;
  • the operating conditions of the circuit (thermometer with thermocouple connected with a meter) can be easily calibrated using ice water, with an accuracy of ± 1 °C;
  • Auto-off function (possible to switch off) saves the battery of the device.
Specification:
  • Inputs: two type K thermocouples;
  • Outputs: switchable: T1, T2, T1-T2 standard banana plugs;
  • Calibration: two external adjustment knobs;
  • Conversion accuracy: 1 mV dc to 1 °;
  • Range: -46 to 982 °C;
  • Resolution: 0,1 ° for the meter to the nearest 0,1mVDC;
  • Battery: Standard 9V;
  • Battery life: 200 hours of continuous operation;
  • Auto Power Off: After 15 minutes;
  • LEDs: green indicates that the device is switched on, the red low battery;
  • Maximum input voltage: 60 V DC, 24 V AC. Note: strong radiofrequency fields can be highly detrimental to the converter.
  • Operating temperature: -34 to 49 °C;
  • Storage temperature: -20 to 60 °C;
  • Isolation probe Teflon, to 260 °C;
  • Accuracy of the system at 24 °C± 3 °C, ambient, after calibration the temperature of ice-water: ± 0.5 °C, -46 to 73 °C; ± 1 °C, 74 to 176 °C; ± 2 °C, 176 to 926 °C.
  • Accuracy of the head: ± 0.5% ± 2 °C, -46 to 982 °C.
  • Thermocouple accuracy: ± 2 °C or ± 0.75%, depending on which value is greater, -34 to 815 °C.