Choose a searcher
  •  - 360

Analizator / elektroniczny zestaw manometrów Fieldpiece SMAN3

2 284.00 PLN (tax excl.)
Quantity
Last items in stock

Application:
  • Pressure and temperature measurement in refrigeration and air conditioning systems
  • Analyzing system operation parameters (e.g. based on overheating and subcooling)
  • Vacuum depth control

Description:

SMAN3 is one of the few analyzers on the market equipped with the function of automatic calculation of the target superheat temperature. Another important advantage is the possibility of calibrating both temperature and pressure, based on information about the type of medium, temperature and atmospheric pressure. This makes calibration extremely easy, even in the field.

SMAN3 also has the function of a vacuum gauge, equipped with an alarm informing about reaching the programmed vacuum level.

SMAN3 is equipped with a resistant casing, covered with rubber, which ensures durability of the device as well as a strong metal hanger. It is extremely resistant to bumps, falls etc.

Features:

  • automatically calculates the target superheat temperature based on the measurements taken
  • calculates and simultaneously displays superheat and subcooling temperature
  • measures pressure and temperature on the liquid and suction side
  • equipped with a large, backlit display showing up to 6 parameters at the same time; resistant to extreme temperatures and legible from a distance of about 6 meters
  • tracks the vacuum pump's running time; length of draining time, may indicate hidden problems
  • support for 39 types of refrigerants
  • included two K-type thermocouples, providing fast and accurate temperature reading
  • extremely long working time on one set of alkaline batteries (up to 135 hours); automatic switch off

Measurements:
  • pressure
  • overheating and subcooling
  • steam saturation temperature
  • temperature (double measurement with 2 thermocouples)
  • target overheating
  • vacuum depth

Included:
  • 2 K-type clamp thermocouples (ATC1)
  • wet bulb thermocouple (ATWB1)
  • dry thermocouple thermometer (ATA1)
  • convenient, waterproof bag that allows you to hide the analyzer without disconnecting the detectors and cables (ANC10)
Specification:
  • Pressure:
    • Connections: standard ¼"SAE
    • Range: 74 cmHgV to 0 to 4 MPa
    • Resolution 1 kPa / cmHg ( 0.1 psi / inHg)
    • Accuracy: 0 to 200 Psig: ± 1 Psi, 0 to 1378 kPa: ± 7 kPa, 200 to 500 Psig: ± 0.3% + 1 Psi, 1378 is 3447KPa: ± 0.3 % + 7 kPa
    • The maximum pressure overload: 800 psig
    • Units: Psig, kPa, inHg, cmHg
  • Vacuum
    • Connection: standard ¼ "SAE
    • Range: 50 to 9999 microns
    • Resolution: 1 micron (50 to 2000 microns) , 250 microns (2001 to 5000 microns) and 500 microns (5001 to 8000 microns), 1000 microns (8001 to 9999 microns)
    • Accuracy: ± 10% or ± 10 microns, depending on which the value is greater (from 50 to 1000 microns)
    • The maximum pressure overload: 500 psig
    • Units: microns
  • Temperature:
    • Type detectors: thermocouple type K
    • Range: -60 ° C to 537.0 ° C (-76 ° F to 999.9 ° F)
    • Resolution: 0.1 °C / °F
    • Accuracy (after calibration): ± 0.5 ° C (-60 °C to 93 °C) ± 1.0 ° C (93 °C 537.0 °C) ± 1.0 ° F (-76 °F to 199.9 °F); ± 2.0 °F (200 °F to 999.9 ° F)
  • Refrigerants:
    • R11, R113, R114, R123, R124, R125, R13, R134A, R22, R23, R401A (MP39), R401B, R402A, R402B, R404A, R406A , R407A, R407C, R408A, R409A, R410A, R414B (Hotshot), R416A, R417A, R420, R421A, R421B, R422A, R422B (NU22B), R422C (Oneshot), R422D, R424A, R434A (RS-45), R438A (M099), R500, R502, R503, R507A
  • Other
    • Display size: 12.7 cm (diagonal)
    • Colour: blue
    • Power: 6 AA batteries
    • Auto Power Off: after 30 minutes of inactivity

Data sheet

Producent
Fieldpiece
Ilość zaworów
2
rodzaj wężów
brak